Typical property values (at 23°C and 50 % relative humidity) PLEXIGLAS® superclear 99560 MR2R


Mechanical properties

Value

Unit

Test standard

Density

1.19

g/cm³

ISO 1183

Impact strength (Charpy)

15

kJ/m²

ISO 179/1fu

Notched impact strength (Izod)

1.6

kJ/m²

ISO 180/1A

Tensile strength
(a) -40 °C
(b) 23 °C
(c) 70 °C


100
72
35



MPa


ISO 527-2/1B/5
*) ISO 527-2/1B/50

Elongation at break

4.5

%

ISO 527-2/1B/5

Flexural strength
Standard test specimen
(80 x 10 x 4 mm)

105

MPa

ISO 178

Compressive yield stress

103

MPa

ISO 604

Modulus of elasticity
(short-term value)

3300

MPa

ISO 527-2/1B/1

Indentation hardness
H961/30

175

MPa

ISO 2039-1

Abrasion resistance in
Taber abrader test
(100 rev.; 5.4 N; CS-10F)

< 1

% Haze

ISO 9352

Pencil hardness

6H²

-

ASTM 3363
ISO 15184
KS D6711:1992

Acoustical properties

Value

Unit

Test standard

Sound velocity
(at room temperature)

2700...2800

m/s

-

Optical properties

Value

Unit

Test standard

Transmittance τD65

> 93

%

DIN 5036
Part 3

UV transmission

< 1

%

-

Reflection loss in the visible range (for each surface)

3.3

%

-

Haze

< 0.5

%

ASTM 1003

Absorption in the visible range

< 0.05

%

-

Refractive index nD20

1.491

-

ISO 489

Inclusions

Number of defects

Unit

Test method

Ø: 0,10 mm to 0,25 mm

≤ 30

per m²

Magnification lens

Ø: 0,25 mm to 0,65 mm

≤ 7

per m²

Magnification lens

Ø: 0,65 mm to 1,65 mm

≤ 1

per m²

Magnification lens

Electrical properties

Value

Unit

Test standard

Volume resistivity

> 1015

ohm . cm

DIN VDE 0303/3

Surface resistivity

> 1012

ohm

DIN VDE 0303/3

Dielectric strength (1 mm specimen thickness)

~ 30

kV/mm

DIN VDE 0303,
Part 2

Dielectric constant
bei 50 Hz
bei 0,1 MHz


3.7
2.8


-
-


DIN VDE 0303,
Part 4

Dissipation factor
at 50 Hz
at 0,1 MHz


0.06
0.03


-
-


DIN VDE 0303,
Part 4

Thermal properties

Value

Unit

Test standard

Coefficient of linear thermal expansion
for 0...50 °C

7 . 10-5
(= 0.07)

1/K
(mm/m °C)

DIN 53752-A

Thermal conductivity

0.19

W/mK

DIN 52612

U-value, for thickness
1 mm
2 mm


5.8
5.6



W/m²K



DIN 4701

Specific heat

1.47

J/gK

-

Max. permanent service temperature

70

°C

-

Ignition temperature

430

°C

DIN 51794

Fire rating
(thickness ≥ 1.6 mm)

HB

UL 94

Vicat softening temperature

102

°C

ISO 306,
Method B50

"Heat deflection" temperature under load (HDT)
(a) deflection 1.8 MPa
(b) deflection 0.45 MPa



90
95



°C
°C



ISO 75
ISO 75

2 Results may vary with different pencil sets. 6H was certified internally as well as by an independent external material testing laboratory.